Skip to main content

Link OAM

Link OAM tests link-layer Ethernet OAM. It verifies that equipment correctly discovers an OAM neighbor and supports keepalives, loopback, and link events. The protocol is especially useful for testing carrier Ethernet services and troubleshooting L2 access.

Table 207 — Link OAM Parameters

NameDescriptionValue
Instance IDLink OAM instance identifierSpecify a number and bind it to the interface
ModeOAM operating modeactive for active initiation, or the mode used on the testbed
Keepalive intervalOAM keepalive interval1 second by default
Hold timeTime without keepalives before the neighbor is lost5 seconds by default
Max PDU sizeMaximum OAM PDU size1518 bytes by default
Loopback supportRemote loopback supportEnable to test loopback scenarios
Link events supportLink-event supportEnable to test fault events
Variable retrievalVariable retrieval supportEnable if the equipment uses this mechanism
Unidirectional supportUnidirectional-event supportEnable when testing one-way failure diagnostics
OUIVendor identifierSet as required
Vendor infoAdditional vendor informationUsed in specialized testbeds

After starting the task, check the OAM session state and OAM PDU counters. If the neighbor does not come up, first check L2 connectivity, the VLAN, and the OAM mode at both ends.