CFM (IEEE 802.1ag)

CFM (Connectivity Fault Management) provides service-level Ethernet OAM under IEEE 802.1ag. In Peresvet ST, CFM is configured on the Control Plane network interface, not as a separate protocol-tree instance. Enable Continuity Check and specify the Maintenance Domain and Maintenance Association.

Table 208 — CFM Interface Parameters

NameDescriptionValue
Continuity Check enabledEnable CFM Continuity Check on the interfaceToggle
MD levelMaintenance Domain level0–7
CC intervalContinuity Check interval3.3 ms / 10 ms / 100 ms / 1 s / 10 s / 1 min / 10 min
VLAN priority (PCP)802.1p priority for CFM frames0–7
Sequence numberingCCM sequence numberingEnable/disable
MD name / MD name formatDomain name and formatNONE / DNS / MAC_INT / STRING
MA name / MA name formatRequired association name and its formatVLAN / STRING / UINT16 / VPN_ID / ICC
MA IDMaintenance Association identifier0–65535

MD/MA name formats must match the expected configuration values; token case is significant. After starting, inspect the Control Plane: CFM dashboard and the events/logs for CCM establishment and connectivity loss.